Abrasion Resistant Epoxy Putty
Professional Use

Abrasion Resistant Epoxy Putty

Product line:
Two-Component Epoxy Adhesive for Industrial & Civil Engineering
Features:
ThixotropicCivil Engineering & ConstructionWet SurfacesJoint FillerSealant

For use as joint filler for UFC panels, and for filling and repairing concrete defects and gaps.

Features

CE-58 (W)・CP-01

・Abrasion resistance equivalent to UFC panels.
・Excellent adhesion to concrete.
・Solvent free - no volatile components.
・Excellent water and chemical resistance after cured.

Low VOC / Formaldehyde Emission
Compliant with JAIA F★★★★ and 4VOC standards – Japan’s strictest safety criteria for indoor air quality.
Suitable for use in living spaces requiring low chemical emissions.

Typical Applications

・Joint filling grout for UFC (ultra high strength fiber reinforced concrete) panels.
・Filling and Repair of Concrete Defects and Gaps.
・Wear Prevention for Water-Resistant Areas.
・Bolt Hole after treatment for UFC Panels installations.

Properties

CE-58 (W) CP-01
Base Resin Hardener Filler
Main Component Modified Epoxy Resin Modified Polyamine Ceramic Powder
Appearance Colorless, Transparent Liquid Pale Yellow, Liquid Gray Powder
Mix Ratio Base Resin:Hardener:CP-01=2:1:5
Pot Life at 20℃ 30min
For pot life at 30℃:Please contact us separately.

Pot Life Curing Time at Temperatures

Temperature CE-58 (W)+CP-01
Pot Life
(100ml)
Tack-Free Time
(10ml)
Curing Time
(10ml)
5℃ 80min 16h 48h
10℃ 60min 5h 24h
20℃ 30min 3h 8h
Curing conditions: 20℃ for 7 days
Test temperature: 20℃

Cured Material Properties

Unit CE-58 (W) +CP-01
Internal Standard Test Procedure
Specific Gravity 1.7±0.2 JIS K 7112
Compressive Yield Strength N/㎟ ≧60 JIS K 7181
Tensile Shear Strength N/㎟ ≧10 JIS K 6850
Charpy Impact Strength kJ/㎡ ≧1.5 JIS K 7111
Hardness HDD ≧80 JIS K 7215
Curing conditions: 20℃ for 7 days
Test temperature: 20℃

Taber Abrasion Tester

Type Abrasion Loss
CE-58 (W)+CP-01 0.30g
UFC 0.28g
Number of Cycles: 1,000 (70 rpm)
Abrasive Wheel: H-22
Load: 500g

Adhesive Strength (BRI Method)
BRI = Building Research Institute (Japan)

Unit Concrete / SUS
Dry Surface N/㎟ 3.4 (Concrete Failure)
Wet Surface N/㎟ 3.3 (Concrete Failure)
Bonding Area: 40mm × 40mm
Prior to testing, the bonded specimen is trimmed along the outer edge using a diamond cutter.

Steel Ball Drop Impact Test

Drop Hight Conditions
30㎝ No Failure
150㎝ No Failure
250㎝ No Failure
The coating is applied and cured to a concrete plate with a thickness of 10 mm.
A 289 g steel ball is dropped 30 times onto the coating from the specified heights.