Products

Professional Use
Abrasion Resistant Epoxy Putty
For use as joint filler for UFC panels, and for filling and repairing concrete defects and gaps.

Features
CE-58 (W)・CP-01
・Abrasion resistance equivalent to UFC panels.
・Excellent adhesion to concrete.
・Solvent free - no volatile components.
・Excellent water and chemical resistance after cured.

Low VOC / Formaldehyde Emission
Compliant with JAIA F★★★★ and 4VOC standards – Japan’s strictest safety criteria for indoor air quality.
Suitable for use in living spaces requiring low chemical emissions.
Typical Applications
・Joint filling grout for UFC (ultra high strength fiber reinforced concrete) panels.
・Filling and Repair of Concrete Defects and Gaps.
・Wear Prevention for Water-Resistant Areas.
・Bolt Hole after treatment for UFC Panels installations.
Properties
CE-58 (W) | CP-01 | ||
---|---|---|---|
Base Resin | Hardener | Filler | |
Main Component | Modified Epoxy Resin | Modified Polyamine | Ceramic Powder |
Appearance | Colorless, Transparent Liquid | Pale Yellow, Liquid | Gray Powder |
Mix Ratio | Base Resin:Hardener:CP-01=2:1:5 | ||
Pot Life at 20℃ | 30min |
Pot Life Curing Time at Temperatures
Temperature | CE-58 (W)+CP-01 | ||
---|---|---|---|
Pot Life (100ml) |
Tack-Free Time (10ml) |
Curing Time (10ml) |
|
5℃ | 80min | 16h | 48h |
10℃ | 60min | 5h | 24h |
20℃ | 30min | 3h | 8h |
Test temperature: 20℃
Cured Material Properties
Unit | CE-58 (W) +CP-01 | ||
---|---|---|---|
Internal Standard | Test Procedure | ||
Specific Gravity | 1.7±0.2 | JIS K 7112 | |
Compressive Yield Strength | N/㎟ | ≧60 | JIS K 7181 |
Tensile Shear Strength | N/㎟ | ≧10 | JIS K 6850 |
Charpy Impact Strength | kJ/㎡ | ≧1.5 | JIS K 7111 |
Hardness | HDD | ≧80 | JIS K 7215 |
Test temperature: 20℃
Taber Abrasion Tester
Type | Abrasion Loss |
---|---|
CE-58 (W)+CP-01 | 0.30g |
UFC | 0.28g |
Abrasive Wheel: H-22
Load: 500g
Adhesive Strength (BRI Method)
BRI = Building Research Institute (Japan)
Unit | Concrete / SUS | |
---|---|---|
Dry Surface | N/㎟ | 3.4 (Concrete Failure) |
Wet Surface | N/㎟ | 3.3 (Concrete Failure) |
Prior to testing, the bonded specimen is trimmed along the outer edge using a diamond cutter.
Steel Ball Drop Impact Test
Drop Hight | Conditions |
---|---|
30㎝ | No Failure |
150㎝ | No Failure |
250㎝ | No Failure |
A 289 g steel ball is dropped 30 times onto the coating from the specified heights.